Download Agilent 35670A Analyzer (operators) PDF

Read or Download Agilent 35670A Analyzer (operators) PDF

Best nonfiction_6 books

Mastermind: the many faces of the 9 11 architect, Khalid Shailk Mohammed

The bestselling writer of Shadow struggle and wasting Bin encumbered exposes the sinister Al Qaeda mastermind at the back of Sept. 11. Khalid Shaikh Mohammed, the architect of the Sep 11 assaults, has performed a few of the largest terrorist plots of the previous two decades, together with the 1993 global exchange heart bombing, the Millennium Plots, and the beheading of Daniel Pearl.

Empowerment and Atiyoga

This booklet used to be composed to aid Western scholars who're taking empowerments often. The booklet will pay realization specifically to the that means of the fourth empowerment, which itself is the direct that means of Mahamudra and Maha Ati (Dzogpa Chenpo). It provides translations of the ritual texts used to provide key empowerments within the Nyingma process and, in particular, offers the foundation empowerment textual content of the Longchen Nyingthig cycle of innermost Dzogchen.

Additional info for Agilent 35670A Analyzer (operators)

Sample text

Scale references If you do not want to use autoscaling, you can select top, center, or bottom scale reference. The analyzer keeps this reference, regardless of your choice of y-units/division. For example, if you are viewing frequency response data on the active trace, setting a top reference of 20 dB means that the top of the line in the display graticule is always at +20 dB. If you change the Y per div value, the top of the scale remains at +20 dB and the bottom of the scale changes accordingly.

Input range tracking You can use input range tracking to reference the scale to the input range currently in use. This behavior varies according to the trace coordinate you’ve selected: • For linear magnitude traces, the bottom reference always stays at zero. The Y per div is adjusted so the top of the scale is greater than or equal to the current input range. • For logarithmic magnitude and dB magnitude traces, the top reference always stays at the current input range. • For real and imaginary traces, the center reference always stays at zero.

3 Press [START RPM USAGE], then press one of the following: [RPM INCREASING] for a runup measurement, or [RPM DECREASING] for a rundown measurement. 4 Press [Rtn] [RPM STEP SIZE] [RPM] to specify how often the analyzer should add a new measurement to the map. 5 Activate all traces you want to view as a map, then press [Scale] [AUTOSCALE ON OFF] to highlight OFF. 6 Press [Disp Format] [WATERFALL SETUP], then press [WATERFALL ON OFF] to highlight ON. 7 Turn on the device-under-test (DUT), then press [Start].

Download PDF sample

Rated 4.60 of 5 – based on 28 votes